USAfixTM - Repair Guide (RG) - Master Email RG
- Check for power to the pump
 Level of Difficulty - HIGH  Estimated Completion Time - 20 minutes
TASKI - ERGODISC 200

Tools Required
Tool 
Screwdriver-phillips
Torx T25
Volt meter (True RMS capable)

Parts Required


Step Procedure & Parts & Tools
1 FOLD THE HANDLE DOWN OVER THE MOTOR. FLIP THE MACHINE OVER.

2 REMOVE THE 9 BOLTS HOLDING THE BOTTOM WEIGHT.
Screwdriver-phillips

3 REMOVE THE 5 BOLTS HOLDING THE BRUSH HOUSING ASSEMBLY

4 REMOVE THE 5 SCREWS HOLDING THE COVER.
Torx T25

5 PULL THE COVER OFF THE MACHINE.

6 LOCATE THE SOLUTION PUMP.

7 DISCONNECT THE 2 BLACK WIRES FROM THE SOLUTION PUMP. INSERT THE LEADS INTO 2 WIRES WITH CONNECTORS COMING FROM THE SOLUTION PUMP. TURN THE UNIT ON AND THE PUMP ON. SET VOLT METER TO AC VOLTAGE. VOLT METER SHOULD READ APPROX. 120 VOLTS. IF POWER TO THE PUMP IS OKAY, REVERSE STEPS 1 THRU 5 TO REASSEMBLE THE MACHINE.
Volt meter (True RMS capable)